Follow Us:
  • NDM2-125P/40002A63A

4P, 63A, 50kA, NDM2-125P/40002A63A, industrial mccb

Manufacturer P/N: NDM2-125P/40002A63A

  • Product Description
Quick Details
  • Types:NDM2-125 series
  • Application:Motor protection type
  • Number of poles:4P
  • Rated ultimate short-circuit breaking capacity/Icu:50kA
  • Rated operating current:63A
  • Operating mechanism :Motor-operated
  • Tripping characteristics:Without tripper function
  • N-pole type of the 4P product:N pole is not be equipped with over-current tripper, and shall be always connected
  • Mounting type:Fixation
  • Wiring type:Front-plate connection

Main Technical Parameters

NDM2-63 series

Rated current of housing Inm (A) 63
Rated current In (A)10, 12.5, 16, 20, 25, 32, 40, 50, 63
Rated insulation voltage Ui (AC V)1000
Rated impulse withstand voltage Uimp (V)800
Rated working voltage Ue (AC V)AC400V, AC690V
Number of poles3
4
Rated limit short-circuit breaking capacity levelLM
Rated limit short-circuit breaking capacity Icu (KA)400V25
5050
690V


Rated operating short-circuit breaking capacity Ics (KA)400V193838
690V


Operating performance (Times)With electricity8000
Without electricity20000


NDM2-125 series

Rated current of housing Inm (A) 125
Rated current In (A)16, 20, 25, 32, 40, 50, 63, 80, 100, 125 
Rated insulation voltage Ui (AC V)1000
Rated impulse withstand voltage Uimp (V)800
Rated working voltage Ue (AC V)AC400V, AC690V
Number of poles3
4
Rated limit short-circuit breaking capacity levelCLMH
Rated limit short-circuit breaking capacity Icu (KA)400V253550
8550
690V

10

Rated operating short-circuit breaking capacity Ics (KA)400V1926386438
690V

8

Operating performance With electricity8000
Without electricity20000


NDM2-250 series

Rated current of housing Inm (A) 250
Rated current In (A)100、125、140、160、180、200、225、250
Rated insulation voltage Ui (AC V)1000
Rated impulse withstand voltage Uimp (V)800
Rated working voltage Ue (AC V)AC400V, AC690V
Number of poles3
4
Rated limit short-circuit breaking capacity levelCLMH
Rated limit short-circuit breaking capacity Icu (KA)400V253550
8550
690V

10

Rated operating short-circuit breaking capacity Ics (KA)400V1926386438
690V

8

Operating performance With electricity8000
Without electricity20000


NDM2-400 series

Rated current of housing Inm (A) 400
Rated current In (A)225A, 250A, 315A,  350A, 400A
Rated insulation voltage Ui (AC V)1000
Rated impulse withstand voltage Uimp (V)800
Rated working voltage Ue (AC V)AC400V, AC690V
Number of poles3
4
Rated limit short-circuit breaking capacity levelCLMH
Rated limit short-circuit breaking capacity Icu (KA)400V35506510065
690V

15

Rated operating short-circuit breaking capacity Ics (KA)400V2638497549
690V

11

Operating performance With electricity7500
Without electricity10000


NDM2-630 series

Rated current of housing Inm (A) 630
Rated current In (A) 400A, 500A, 630A
Rated insulation voltage Ui (AC V)1000
Rated impulse withstand voltage Uimp (V)800
Rated working voltage Ue (AC V)AC400V, AC690V
Number of poles3
4
Rated limit short-circuit breaking capacity levelCLMH
Rated limit short-circuit breaking capacity Icu (KA)400V35506510065
690V

15

Rated operating short-circuit breaking capacity Ics (KA)400V2638497549
690V

11

Operating performance With electricity7500
Without electricity10000


NDM2-800 series

Rated current of housing Inm (A) 800
Rated current In (A) 630A, 700A, 800A
Rated insulation voltage Ui (AC V)1000
Rated impulse withstand voltage Uimp (V)800
Rated working voltage Ue (AC V)AC415V, AC690V
Number of poles3
4
Rated limit short-circuit breaking capacity levelCLMH
Rated limit short-circuit breaking capacity Icu (KA)415

75
100
690V

20

Rated operating short-circuit breaking capacity Ics (KA)415V

5675
690V

15

Operating performance With electricity7500
Without electricity10000


Find more products in China

Importing from China, One-stop purchase replace a step by step learn guide.

Your Email:
Sub:

Remaining:500