Follow Us:
HomeProductsResidual Current Circuit Breakers
Residual Current Circuit Breakers

Residual Current Circuit Breakers

P/N & Price

A Residual Current Circuit Breaker is essentially a current sensing device. It will trip off whenever a fault occurs in the circuit. RCCB is designed such way that it continuously senses and compares for difference in current values (residual current value) between the live and neutral wires.

Product Description

NDM1L-32 Series

The series as including: 

Trip Curve B

NDM1L-32 B* 30mA  NDM1L-32 B* 50mA  NDM1L-32 B* 100mA  NDM1L-32 B* 300mA

Trip Curve C

NDM1L-32 C* 30mA  NDM1L-32 C* 50mA  NDM1L-32 C* 100mA  NDM1L-32 C* 300mA

Trip Curve D

NDM1L-32 D* 30mA  NDM1L-32 D* 50mA  NDM1L-32 D* 100mA  NDM1L-32 D* 300mA


Technical Parameters

Rated current1A  2A  3A  4A  5A  6A  10A  16A  20A  25A  32A 
Poles2P  3P  4P  1P+Neutral  3P+Neutral
Neutral positionRight
StandardIEC 61009-1
Network typeAC and Electronic
Earth-leakage sensitivity30mA  50mA  100mA  300mA
Rated short-circuit breaking capacity6.0KA  4.5KA (Curve D)
CertificationCCC  RoHS 


Trip Curve Chart (NDM1L-32 Series)

Trip Curve BTrip Curve CTrip Curve D
b-curve-ndm1l-32c-curve-ndm1l-32d-curve-ndm1l-32


Poles Frame Width

2P

62.0mm ± 0.6mm
3P88.8mm ± 0.6mm
4P115.5mm ± 0.7mm
1P+Neutral44.5mm ± 0.6mm
3P+Neutral97.8mm ± 0.7mm


NDM1L-100 Series

The series as including: 

Trip Curve C

NDM1L-100 C* 100mA

Trip Curve D

NDM1L-100 D* 100mA


Technical Parameters

Rated current50A  63A  80A  100A
Poles2P  3P  4P  1P+Neutral  3P+Neutral
Neutral positionRight
StandardIEC 61009-1
Network typeAC and Electronic
Earth-leakage sensitivity100mA
Rated short-circuit breaking capacity10.0KA
CertificationCCC  RoHS 


Poles Frame Width

2P

107.4mm ± 0.7mm
3P151.3mm ± 0.9mm
4P195.5mm ± 1.2mm
1P+Neutral80.7mm ± 0.6mm
3P+Neutral168.0mm ± 1.2mm


Trip Curve Chart (NDM1L-100 Series)

Trip Curve CTrip Curve D
c-curve-ndm1l-100d-curve-ndm1l-100


NDB2LE-63 Series

The series as including: 

Trip Curve B

NDB2LE-63 B* 30mA  NDB2LE-63 B* 50mA  NDB2LE-63 B* 100mA  NDB2LE-63 B* 300mA

Trip Curve C

NDB2LE-63 C* 30mA  NDB2LE-63 C* 50mA  NDB2LE-63 C* 100mA  NDB2LE-63 C* 300mA

Trip Curve D

NDB2LE-63 D* 30mA  NDB2LE-63 D* 50mA  NDB2LE-63 D* 100mA  NDB2LE-63 D* 300mA


Technical Parameters

Rated current1A  2A  4A  6A  10A  16A   20A  25A  32A  40A  50A  63A
Poles2P  3P  4P  1P+Neutral  3P+Neutral
Neutral positionRight
StandardIEC 61009-1
Network typeAC and Electronic
Earth-leakage sensitivity30mA  50mA  100mA  300mA
Rated short-circuit breaking capacity10.0KA
CertificationCCC  TUV  CE  RoHS 


Poles Frame Width

2P

70.8mm ± 0.8mm
3P116.1mm ± 0.8mm
4P133.7mm ± 1.2mm
1P+Neutral53.1mm ± 0.5mm
3P+Neutral133.7mm ± 1.2mm


Trip Curve Chart (NDB2LE-63 Series)

Trip Curve BTrip Curve CTrip Curve D
b-curve-ndb2le-63c-curve-ndb2le-63d-curve-ndb2le-63


NDB2LM-63 Series

The series as including: 

Trip Curve B

NDB2LM-63 B* 30mA  NDB2LM-63 B* 100mA  NDB2LM-63 B* 300mA

Trip Curve C

NDB2LM-63 C* 30mA  NDB2LM-63 C* 100mA  NDB2LM-63 C* 300mA

Trip Curve D

NDB2LM-63 D* 30mA  NDB2LM-63 D* 100mA  NDB2LM-63 D* 300mA


Technical Parameters

Rated current1A  2A  3A  4A  5A  6A  10A  16A   20A  25A  32A  40A  50A  63A
Poles2P  3P  4P  1P+Neutral  3P+Neutral
Neutral positionRight
StandardIEC 61009-1
Network typeA and AC
Earth-leakage sensitivity30mA  50mA  100mA  300mA
Rated short-circuit breaking capacity10.0KA
CertificationCCC  TUV  CE  RoHS 


Poles Frame Width

2P

72.0mm ± 1.0mm
3P117.0mm ± 1.0mm
4P135.0mm ± 1.0mm
1P+Neutral54.0mm ± 1.0mm
3P+Neutral135.0mm ± 1.0mm


Rated Voltage

AC230V/240V 2P  1P+Neutral
AC400V/415V 3P  4P  3P+Neutral


Trip Curve Chart (NDB2LM-63 Series)

Trip Curve BTrip Curve CTrip Curve D
b-curve-ndb2lm-63c-curve-ndb2lm-63d-curve-ndb2lm-63


NDB6LM-40 Series

The series as including: 

Trip Curve B

NDB6LM-40 B* 30mA  NDB6LM-40 B* 100mA  NDB6LM-40 B* 300mA

Trip Curve C

NDB6LM-40 C* 30mA  NDB6LM-40 C* 100mA  NDB6LM-40 C* 300mA


Technical Parameters

Rated current6A  10A  16A  20A  25A  32A  40A
Poles1P+Neutral
Neutral positionRight
StandardIEC 61009-1
Network typeA and AC
Earth-leakage sensitivity30mA  100mA  300mA
Rated short-circuit breaking capacity10.0KA
CertificationCCC  TUV  CE  CB  RoHS 


Poles Frame Width

1P+Neutral36.2mm ± 0.4mm


Rated Voltage

AC 230V1P+Neutral


Trip Curve Chart (NDB6LM-40 Series)

Trip Curve BTrip Curve C
b-curve-ndb6lm-40c-curve-ndb6lm-40


Find more products in China

Importing from China, One-stop purchase replace a step by step learn guide.

Your Email:
Sub:

Remaining:250