Product Description
Metal shell series ALS-M
Actuator type | Image | Actuator type | Image | Actuator type | Image | Actuator type | Image |
Rounded plunger | Roller plunger | Roller plunger | Twist lever | ||||
Adjustable twist lever | Rod actuator | Spring rod | Palpus |
Note: the number of products poles is one normally open and one normally closed (1NO1NC).
Go download center and get the products datasheet
How does the limit switch wiring?
Description | Image show |
Step 1: unscrew the screw, take off the cover | |
Step 2: install the wire through cable gland | |
Step 3: wiring | |
Step 4: tighten the screws of the cover |
Note:
- Tightening torque 0.5~0.6Nm of contact model.
- Tightening torque 0.5~0.6Nm of cover.
- Avoid the damage of seal ring, pls. even tighten the screws.
Technical Data of ALS1-M
Standards | IEC60947-5-1 GB14048.5 |
Rated insulation voltage Ui | 400V AC |
Rated impulse withstand voltage uimp | 1890V AC 50Hz. 1min |
Conventional thermal current Ith | 10 Ampere |
Product certification | CCC, CE, RoHS |
Mechanical endurance | More than 10 million times |
Electrical endurance | 0.5 million times/AC-15 at 240V/3A |
Operation temperature | -20℃ ~70℃ |
Humidity | < 95%RH |
Protection class | IP65 |
Operating frequency | 7,200 times/hour (mechanical endurance) |
Shock amplitude | ≤ 10g |
Impact amplitude | 10~55Hz 1.5mm |
Contact resistance | < 25mΩ |
Contact material | AgNi10/Cu |
Wire specifications | 2×(0.5…0.75)mm2 1×(0.5…1.5)mm2 |
Plastics shell series ALS-P
Actuator type | Image | Actuator type | Image | Actuator type | Image | Actuator type | Image | Actuator type | Image |
Roundedplunger | Roller plunger | Roller lever | Angular roller lever | Twist lever | |||||
Adjustable twist lever | Rod actuator | Spring rod | Rounded plunger | Roller plunger |
Note: the number of products poles is one normally open and one normally closed (1NO1NC).
Go downland center and get the products datasheet
How does the limit switch wiring?
Step 1: Unscrew the screw, take off the cover | |
Step 2: Install the wire through cable gland | |
Step 3: Wiring | |
Step 4: Tighten the screws of the cover | |
Step 5:Tighten the cable gland |
Note:
- Tightening torque ≤0.7Nm of contact type.
- Tightening torque ≤1Nm of cover.
- Pay attention to cover installed.
Technical Data of ALS1-P
Standards | IEC60947-5-1 GB14048.5 EN50047 |
Rated insulation voltage Ui | 400V AC |
Rated impulse withstand voltage uimp | 1890V AC 50Hz. 1min |
Conventional thermal current Ith | 10 Ampere |
Product certification | CCC CE RoHS |
Mechanical endurance | More than 10 million times |
Electrical endurance | 0.5 million times/AC-15 at 240V/3A |
Ambient temperature | -25℃ ~70℃ |
Humidity | < 95%RH |
Protection class | IP67 |
Operating frequency | 6,000 times/hour (Mechanical Endurance) |
Shock amplitude | ≤ 10g |
Impact amplitude | 10~55Hz 1.5mm |
Contact resistance | < 25mΩ |
Contact material | AgNi10/Cu |
Safety circuits | Yes |
Wire specifications | 2×(0.5…0.75)mm2 1×(0.5…1.5)mm2 |